BACK UP YOUR DATA BEFORE UPDATING YOUR FIRMWARE
For use with Web Editor v1.2
There is a bug related to the Bank Presets when updating from the v3.8 firmware, which causes it to load wrongly.
Solution: After backing up your data in v3.8, update the firmware to v3.9, and then reload your data in v3.9.
Fixed
[2021-11-09] Aux Switch T+R in Omniport 3 not working for the MC8
Fixed
[2021-11-09] Triggering T+R for Aux switches is sometimes unreliable
Fixed
[2021-11-11] Bug in Global Message Parameter Update function
Fixed
[2021-11-11] Bug in MIDI Type B setting for Omniport
Fixed
[2021-11-12] Bug in expression pedal message
When pedal is left in heel down or toe down positions, the heel down or toe down messages will engage when the pedal is moved.
Fixed
[2021-11-12] 0 BPM is displayed in the MC8 when controller boots up and MIDI clock is not in use.
Fixed
[2021-11-05] Expression Scaled feature sends the same value for both positive and negative curves.
Fixed
[2021-11-05] Looper Mode switch option need to be selected in order for Looper Mode to work. If it is turned off, Looper mode does not engage
Fixed
[2021-11-05] Looper Mode for aux switches is currently not available, but we will update the aux switches to always have minimal delay.
Fixed
[2021-11-05] When Custom Bank Sequence
is turned on, saving on the editor will cause it to save it to the wrong bank.
Please turn off the Custom Bank Sequence
when editing.
Fixed
[2021-11-05] Bank Change Mode
displays wrong bank name when Custom Bank Sequence
is active.
SysEx presets need to be reprogrammed.
CC Value Scroll messages need to be reprogrammed.
Added Utility
message type, which allows you to:
Manage Scroll Counter values
Increase/Decrease MIDI Clock BPM by 1
Clear all Preset Toggles globally
Set Preset Message Scroll
index for selected Preset
PC Scroll
and CC Scroll
now has a wrap-around setting to allow you to wrap-around the values (go to min when value is at max), or stay at the limits (value will not increase further when at max)
Added Step Value
parameter in CC Value Scroll
message type, which allows you to increase/decrease the counter value by a specified step value.
Random Waveform
added to Waveform Generator
Added Model ID
option for AxeFX Tuner and integration to select between AxeFX III
or FM3
Added Invert Waveform
option in WaveForm Generator message type
Inverts the waveform shape
New AxeFX Integration
message type for MC6MKII
and MC8
Enters a mode where you can select Presets and Scenes on the AxeFX 3. Scene and Preset names are retrieved from the AxeFX3.
Increased the max length for a SysEx message
sent from a preset from 47 to 63.
Added 0.25
0.50
0.75
decimal increments when using the MIDI Clock
message type to set a pre-set BPM.
Added Ignore Bank Preset On Enter
and Ignore Bank Preset On Exit
parameter in the Bank Jump
messages. If enabled, Bank Presets will not execute when jumping banks with that message
Control Change
message type now has the option to use CC Value based on a selected Expression pedal position
Looper Mode
message type now lets you select what switches to apply this to
Added Preset Q, R, S, T, U, V to Set Toggle
message for MC8
Added All Notes
option for Note Off
message type, which will send a Note Off
command to all 128 Notes.
Engage Preset
can now call the same Preset, as long as the action is different.
Expression Waveform Timer
and Expression Sequencer Timer
message types for Expression Presets to control your Waveform Engines
and Sequencer Engines
interval times with your expression pedal
Added Expression CC (Scale)
message type
Scale your CC response to a logarithmic or exponential response
Added Pitch Bend
, PC Heel Down
and PC Toe Down
message types
Added Preset Toggle Groups
feature
Add your Presets to Toggle groups to have their toggle positions stay in sync with every preset in that group. For example, if Preset A in Bank 1 and Preset D in Bank 4 are in Toggle Group 1, when Bank 1 Preset A is toggled, Bank 4 Preset D will be toggled as well
Added %BP
Placeholder to display the current MIDI Clock BPM in your Preset Name
New Preset Shift feature. Preset messages can be selected to engage only when the Preset is Shifted.
More info here: https://forum.morningstar.io/t/new-toggle-feature-shift/1632/13
Added On First Engage
action type
A preset is first engaged
when it is selected for the first time. Subsequent presses on the same preset will not trigger the On First Engaged
messages, until a different preset is selected and then the preset is selected again.
Added On Disengage
action type
A preset is disengaged
when a different preset is selected. A bank change will not disengage a preset.
Added Bank Enter Only Once
and Bank Exit Only Once
events in Bank Presets. These events will only trigger once on each controller boot up.
Added MIDI Message Converter
feature, which allows you to re-route incoming PC, CC and Note messages to different PC/CC/Note numbers and channels.
Added Load last used bank on power up
feature in global settings
Data Dump format now in json.
This allows data to be loaded across different devices
Added SysEx API for external applications.
Added multi message copying feature
Added Light mode
Fixed bug where Msg16 does not load in the editor
New Controller Settings backup function
New Activity monitor
feature
Monitor the execution of messages for your Presets and Bank Presets, so you know what exactly is happening when you engage a preset
MSB and LSB value calculator under Preset Settings
>> Tools
New Global Message Parameter Update function
Update Preset Messages with the same parameters together
New SysEx creation utility
under Preset Settings
>> Tools
to help you create a Preset sending SysEx messages
Updated User Library
interface
New Data Backup Manager
feature in Controller Backup
Pick and choose banks from your backup files before uploading them to the Controller
Web Editor can now be installed as a Chrome Web App, which will be available when you are offline
New Preset Template Utility
under Preset Settings
>> Tools
Select from a list of example templates to populate your preset settings