[op2: 05h] Other Data Preset
Code Block | ||
---|---|---|
| ||
F0 -- SysEx Start 00 -- Manufacturer ID 1 21 -- Manufacturer ID 2 24 -- Manufacturer ID 3 xx -- Device Model ID 00 -- Ignore 70 -- Opcode 1 - 0x70 05 -- Opcode 2 - Update Preset Other Data xx -- Opcode 3 - Preset Number (A = 0, B = 1 ...) xx -- Opcode 4 - Message Number (0-15, or 0x00 - 0x0F) 00 -- Opcode 5 - Message Type (See MESSAGE TYPES) 00 -- Opcode 6 - Whether to save to memory. 7F = Save. 00 -- Opcode 7 xx -- Transaction ID 00 -- Ignore 00 -- Ignore pp -- Preset Toggle: 7F = ON, 00 = OFF, Other = OFFIGNORE pp -- Preset Blink: 7F = ON, 00 = OFF, Other = OFFIGNORE pp -- Preset Message Scroll Mode: 7F = ON, Other = OFF, 00 = OFF, Other = IGNORE pp -- Preset Global Toggle Group: 00 = Independent, 01-10 = Groups 1 to 16, Other = IGNORE [Ignore this if not using the PRO model] pp -- Pos 1 LED Color (PRO only) F7 = IGNORE pp -- Pos 2 LED Color (PRO only) F7 = IGNORE pp -- Shift LED Color (PRO only) F7 = IGNORE pp -- Pos 1 Text Color (PRO only) F7 = IGNORE pp -- Pos 2 Text Color (PRO only) F7 = IGNORE pp -- Shift Text Color (PRO only) F7 = IGNORE pp -- Pos 1 Background Color (PRO only) F7 = IGNORE pp -- Pos 2 Background Color (PRO only) F7 = IGNORE pp -- PresetShift GlobalBackground ToggleColor Group: 00 = Independent, 01-10(PRO only) F7 = GroupsIGNORE 1 to 16 yy -- CheckSum F7 -- SysEx End |
...
[op2: 11h] Display message on LCD
Displays a custom message of up to 20 characters in the controller’s LCD.
Code Block |
---|
F0 -- SysEx Start
00 -- Manufacturer ID 1
21 -- Manufacturer ID 2
24 -- Manufacturer ID 3
xx -- Device Model ID
00 -- Ignore
70 -- Opcode 1 - 0x70
11 -- Opcode 2 - Display message on LCD
00 -- Opcode 3
00 -- Opcode 4 - Duration to display message. Increments of 100ms. Value of 10 = 1000ms.
00 -- Opcode 5
00 -- Opcode 6
00 -- Opcode 7
00 -- Ignore
00 -- Ignore
00 -- Ignore
pp -- Payload. Message in ASCII code up to 20 characters
pp
....
pp
yy -- CheckSum
F7 -- SysEx End |
...
Code Block |
---|
MC6 0x03
MC8 0x04
MC3 0x05
MC6PRO 0x06 |
Action Types
This section specifies the Action IDs required when programming Preset Messages
...