Presets on the Timeline can be set to follow the incoming MIDI Clock, or follow its own pre-set BPM. If the MIDICL
setting is turned ff for the preset, it will not respond to MIDI Clock.
...
Connecting Strymon TRS MIDI Devices
It is possible to use a standard TRS cable to connect the Omniport directly to the Strymon TRS MIDI IN port. The Omniport settings needs to be set to “MIDI OUT - Standard”.
Alternatively, you can use a Type A DIN5 to TRS cable adaptor to connect the DIN5 MIDI OUT port directly.
However, do note that the Strymon TRS MIDI devices do not have an inbuilt opto-isolator, so there might be potential for ground loops. More info: There is MIDI Noise in my Audio signal
Strymon sells a MIDI Exp cable with a built-in isolator for their TRS MIDI devices: https://www.strymon.net/product/midi-exp-cable/
Engaging Looper mode in Timeline
Looper mode is engaged on the Timeline by holding down the Tap footswitch.
C#81 with values 0 and 127 will trigger the Tap footswitch press and release function respectively.
So, to simulate a long press to trigger the tuner, you can do this:
...
You'll need to hold down the switch on the MC6 and then release it to simulate the same press and release on the Timeline.
Alternatively, you can use a Press action for both, and then add a delay inbetween to simulate a press/release on the Timeline with just a Press action on the MC6:
...
Strymon Volante
Problem
After updating a patch/preset on the Volante, the Volante will not engage any of the patches which have been updated.
Solution
When updating a patch, make sure that the preset is not saved in Bypass mode. If so, when a PC message is sent to the Volante, it will load the preset but in bypass.