Code Block |
---|
F0 -- SysEx Start 00 -- Manufacturer ID 1 21 -- Manufacturer ID 2 24 -- Manufacturer ID 3 xx -- Device Model ID 00 -- Ignore 70 -- Opcode 1 - 0x70 10 -- Opcode 2 - Update Current Bank Name 00 -- Opcode 3 00 -- Opcode 4 - Whether to save to memory. 7F = Save. 00 -- Opcode 5 00 -- Opcode 6 00 -- Opcode 7 xx -- Transaction ID 00 -- Ignore 00 -- Ignore pp -- Payload. Bank name in ASCII code pp .... pp yy -- CheckSum F7 -- SysEx End |
[op2: 11h] Display message on LCD
Code Block |
---|
F0 -- SysEx Start
00 -- Manufacturer ID 1
21 -- Manufacturer ID 2
24 -- Manufacturer ID 3
xx -- Device Model ID
00 -- Ignore
70 -- Opcode 1 - 0x70
11 -- Opcode 2 - Display message on LCD
00 -- Opcode 3
00 -- Opcode 4
00 -- Opcode 5
00 -- Opcode 6
00 -- Opcode 7
00 -- Ignore
00 -- Ignore
00 -- Ignore
pp -- Payload. Message in ASCII code up to 20 characters
pp
....
pp
yy -- CheckSum
F7 -- SysEx End |
[op2: 21h] Get Preset Short Name
...